664 2M-Z18642 Owners Manual 2790 E-Max Dual Thermal Brewer
TROUBLESHOOTING SUGGESTIONS
DESCRIPTION OF PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY
No lights or heat
Unit not plugged in or circuit breaker
tripped
Reset circuit breaker
Plug brewer into electric power
Power switch OFF Turn power switch ON
No heat Hi-limit safety tripped
Allow brewer to cool, verify water level,
reset hi-limit
Brewer overows
Water level probe corroded Clean water level probe
Poor ground connection Verify ground connection
Dirt in inlet valve or valve damaged Replace inlet valve
Brew valve damaged Replace brew valve
Brew chamber overows
Too many paper lters or wrong lter
used
Use one genuine Bloomeld paper lter
per brew
Chamber discharge hole plugged Clean brew chamber
Improper programming Correct program (see pg. 12)
Heats slow
Connected to wrong voltage Verify supply voltage
Scale build-up on heating elements De-lime hot water tank
Damaged heating element Replace element
Slow to ll
Insufcient water pressure
Brewer must be operated on a dedicated
water line. Other equipment on line may
be robbing water volume.
Plugged water line strainer Clean strainer
Poor coffee quality
Improper programming Correct programming
Also:
Keep brewer and servers clean.
Install a taste and odor lter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind and amount of coffee
per brew.