Bloomfield 2030 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekspresy do kawy Bloomfield 2030. Bloomfield 2030 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
PRINTED IN UNITED STATES OF AMERICA
p/n 73902 Rev. F ECN-12817 M653 050208 cps
653
OWNERS MANUAL
for
E-Max™
TEA BREWERS
MODELS
2030
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 2030
Tea Brewer
with optional
8799 Dispenser
E-Max BREWERS are covered under
U. S. Patents #5704275, 5862738, 6095031.
Other U.S. Patents and Canadian Patents Pending
Przeglądanie stron 0
1 2 3 4 5 6 ... 25 26

Podsumowanie treści

Strona 1

PRINTED IN UNITED STATES OF AMERICA p/n 73902 Rev. F ECN-12817

Strona 2 - WARRANTY STATEMENT

PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water temperature on the screen, E-Max T™ brewer must be ON

Strona 3 - k 1500 watts in Canada

8. Clock A. Time – Battery Backup. The E-Max T™ has a battery backup system which will maintain the proper time during power

Strona 4

OPERATION (continued) 10 12. View Filter Statistics: To view filter statistics, turn the brewer off. Press and hold the 1st key (Brew), an

Strona 5

CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow bre

Strona 6 - INSTALLATION INSTRUCTIONS

FUNCTION 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller.

Strona 7

SERVICING INSTRUCTIONS — PLUMBING (continued) 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2030 6 GASKET, TAN

Strona 8 - OPERATING INSTRUCTIONS

SERVICING INSTRUCTIONS - ELECTRICAL FUNCTION 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2. Au

Strona 9 - Brew complete

SERVICING INSTRUCTIONS - ELECTRICAL (continued) 15 ITEM DESCRIPTION PART N0. USED ON 3 PROBE, TEMPERATURE 83480 ALL 4 THERMOSTAT, HI-LIMIT SAFETY (1

Strona 10 - OPERATION (continued)

SERVICING INSTRUCTIONS — DE-LIMING HEATER TANK 1. Disconnect brewer form the electrical supply. Turn off the water supply and disconnect w

Strona 11

TROUBLESHOOTING SUGGESTIONS If the E-Max T™ goes into the error mode as outlined below, it will likely be necessary to reset the brewer in order to te

Strona 12

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f

Strona 13 - CLEANING INSTRUCTIONS

E-Max T™ TEST PROGRAM 18 Instructions for testing procedures for the following system components (using the E-Max T™ Built-In Diagnostic): Ele

Strona 14

E-Max T™ TEST PROGRAM (continued) 19 E. LED Test The display should read “Testing LED’s”: Individual LED’s will be tested individually, begi

Strona 15

EXPLODED VIEW & PARTS LIST 20

Strona 16 - WARNING:

EXPLODED VIEW & PARTS LIST (continued) 21 ITEM PART # DESCRIPTION QTY 1 8783-1 FAUCET, HOT WATER 1 2 83500 TANK ASSEMBLY, 120V 1 3 83

Strona 17

WIRING DIAGRAMS (continued) 22

Strona 18

NOTES 23

Strona 19 - TROUBLESHOOTING SUGGESTIONS

PRINTED IN UNITED STATES OF AMERICA Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-689-5700Fax:

Strona 20 - E-Max T™ TEST PROGRAM

TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consi

Strona 21

FEATURES AND OPERATING CONTROLS 2 Features & Operating Controls

Strona 22

WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not o

Strona 23

INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspect all

Strona 24 - WIRING DIAGRAMS (continued)

INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes

Strona 25

OPERATION IMPORTANT: All E-Max T™ brewers are tested and set at the factory. If programming adjust-ments are necessary, refer to the E-Max™ Prog

Strona 26

OPERATION (continued) WARNING: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury f

Komentarze do niniejszej Instrukcji

Brak uwag